Premier Keypad Functions:
- Lock the entire keypad: Press the INSIDE button for 5 seconds and it will lock the entire keypad. Press the INSIDE button again for 5 seconds to unlock the keypad.
- Lock everything but the lights: Press the OUTSIDE button for 5 seconds and it will lock the entire keypad except the lights. Press the OUTSIDE button again for 5 seconds to unlock the keypad.
- Heater Sensor Control: With the power off, press TIME UP for 10 seconds. It will show the sensor control maximum heater temperature. The default is 110c. Press TIME up to adjust the temperature. The range is 100C - 1200C.
- Temperature Offset: With the POWER OFF, press TEMP UP for 10 seconds. It will show the default offset temperature of 5C. You can adjust the offset by pressing TEMP UP/DOWN. The range is 0 -20.
- Front Outlet for Red Light Commercial Mode: With the POWER on, set the temperature to 40C and press the AUX button for 5 seconds for Commercial Mode: The outlet works for 30 minutes.
- Front Outlet for Red Light Residential Mode: With the POWER on, set the temperature to 50C and press the AUX button for 5 seconds for Residential Mode. The outlet is always on.
- Front Outlet for Add On Full Spectrum Heater: With the POWER on, set the temperature to 60C and press the AUX button for 5 seconds. The outlet works with the other heaters in the sauna.
- 16 Hour Continuous Operation Mode: With the POWER on, set the temperature to 10C and press the AUX button for 5 seconds. The sauna will now run for 16 hours. You can continue to adjust the time between 0-60 minutes and it will count down, but the sauna won’t shut off when it reaches 0. To turn off 16 hour mode, press the POWER button.
- R6: The R6 error code is a memory error in the keypad. It can happen if there is a power surge/fluctuation. To clear the error, hold the Time Down button for 10 seconds. That will clear the error.